Hux requirements#

Draft from Steve, 2026-09-20, plus scale / structure 2026-09-21. Source of truth: this GitHub repo (nova-centauri/hux-robot). Decision log: decisions.md. Architecture is also folded into vision.md, electronics.md, and mechanical.md.

2026-09-28 governing update: no components purchased; stair architecture reopened. Head and leg review supersedes earlier sizing claims. R2/R3/R17 remain requirements, not demonstrated capabilities.

Goal#

Wheeled biped that can climb and descend stairs by: lift one wheeled leg → balance on the planted leg → rotate/place the raised wheel onto the next tread → plant → repeat.

Inspiration: Alex Hattori — STRIDE wheeled biped V2, XRobots, and Steve's shares in research/inspiration.md (Roadrunner, FrRonconi student balancer, Build Some Stuff / Serra). Steal ideas. Do not vendor.

Hard requirements#

IDRequirementNotes
R1Balance on two wheeled legsBaseline stance / teleop
R2Balance on one wheeled legGate before stair cycle
R3Step up or down a 9.5" × 9.5" stepRise and going, nosing to nosing. Stroke owns the rise. The going is what the wheel has to sit in. research/leg-geometry.md.
R4Wi‑Fi telemetryCompanion or bridge
R5RC control via TBS Nano RXBind to FC (or dedicated link into FC)
R6In-wheel brushless FOC driven wheelsESC + BLDC + encoder per wheel. Motor at the rim (R30). Not steppers. SKU TBD.
R7Legs via strong linkages + springsGravity compensation / energy return. Prefer linkage over pure serial belts. A belt, if present, is reduction — not a replacement linkage.
R8Local compute for pathfinding inferenceNeeds cameras; not on the FC
R9CamerasAt least one stream for teleop; stereo / depth later for stairs
R10Electric-only powertrainEntire robot is electric. No ICE, no hybrid.
R11Battery: 8S LiPo, regulated logic railsRetain 33.6 V full / 29.6 V nominal / 26.4 V planning cutoff; exact pack/revision and under-load limits require validation. 2.7–3.3 Ah packaging study, no SKU. 60-V-input-rated regulator class, with transient/regen design. Vendor 15/24 V minimum conflict is recorded in review.
R12Knee + hip swing: CAN QDD / FOC working class (2026-09-26); servo vs stepper+belt is the fallbackNo SKU. Size whichever we pick for one-leg plant load (R36). Powerful / fast / reliable still required. GIM8108-8 is a candidate for these axes — not ordered, not locked. See research/actuators-legs.md.
R13Approximately 6-inch OD real-rubber wheelsWidth/contact profile reopened 2026-09-28 to fix single support. 80 mm dual-contact wheel-foot is an unsourced study allocation. Tire width is not a measured support polygon. No Zantle purchase or wheel SKU.
R14Four manual modes before autonomyPARKED / TWO_WHEEL / LEFT_ONLY / RIGHT_ONLY. Spec: software.md. Gate before open-loop step, pathfinding motion, stair scripts.
R15V1 overall width ~14"Outside-to-outside, wheels included. The head sits inside. Legs and wheels are outside the head.
R16Hip roll remains in the research baselineJoint travel, leverage and ankle support are reopened. Do not buy or ship an inadequate joint merely to preserve the old eight-axis drawing.
R17Controlled one-leg support and return before stairsLateral support moment and fore-aft balance must both be real. A 0.2-second hop is not a substitute. Proposed bench gate: 10-second support, ±10 mm CoM uncertainty and controlled return on both legs.
R18Reuse existing controlExplicit non-goal: writing a novel Hux balance stack from scratch for V1. TBD which we adopt.
R19Prefer cheap COTS stock for primary structureCarbon tubes / rods, metal stock, fasteners. Do not custom-print a spar when off-the-shelf will do. Printed / machined parts are joints, hubs, brackets.
R20Custom parts are draft-friendly3D print now, injection mold later. Avoid undercuts; parting-line awareness; printable orientation.
R21Wire openings and ports through links / bodyCable paths are designed in, not drilled later.
R22Serviceable V1Access to fasteners, batteries, FC, actuators. Replaceable modules over sealed mono-bodies.
R23Several 2D sketch layouts before any Blender / 3D CADHard process gate.
R25Wheel motors sized for reaction speed / torque bandwidthBalance actuator, not max continuous power. 8S bus, CAN. Two wheel motors + drivers must leave room for pose joints, structure, pack, FC, Pi.
R26Leg actuators by axis roleJobs differ. Do not force one type on roll, swing, and knee. Trade: research/actuators-legs.md.
R27Hip-roll actuator = dynamic FOC BLDC / small QDD / fast bus servoWorking V1 class. High-rate torque; ideally backdrivable. Pairs with planted-wheel fore/aft (R17).
R29Axis count follows validated mechanism; MCU does not drive coilsEight-axis old model is rejected for stair procurement. Ten-axis hip/ankle candidate under study. Three classic-CAN buses with a verified mixed-rate schedule; do not budget all nodes at 1 kHz.
R30Wheel BLDC at the wheelHub / coaxial at the rim. Not remote-driven from the hip.
R31kV match is a sizing goal8S + wheel diameter + balance bandwidth. TBD — no invented number.
R32Prefer proximal actuator massKeep any stepper pose motors above the knee. The active ankle-roll candidate explicitly trades added distal mass for a ground-moment load path; account for its mass and inertia before accepting it.
R33If belts: one inside, one outside; integrate pulley where possibleClearance / service / no rub. Face assignment TBD on the 2D set. Draft-friendly printed tooth form (R20) or COTS pulley fallback.
R34Primary upper + lower leg spars are carbon fiber tubesCOTS (R19). Printed / machined fittings at the ends only (hubs, belt mounts, joint flanges). Do not print or mill the spar. Tube OD / wall TBD.
R35V1 envelope up to ~24" tall at full extensionStill must reach a ~9.5" riser with margin (R3). Width is ~14" (R15).
R36Size for single-support loads and complete duty cycleFull load-path/inverse-dynamics calculation, contact margin, mounted thermal limits and transients; ~2× average is only a preliminary heuristic. Peak torque is not a continuous holding allowance.
R37V1 finish line: one 9.5" step, 9 of 10 attempts, from a standstill on the lower tread2026-09-27. A full flight is V2 on the same hardware. North star (stairs) unchanged. Supersedes nothing; names the pass mark for R3.
R381.5 m/s top, 1.0 m/s cruise remains the flat-ground targetBattery-dependent torque-speed reserve is unverified on hardware. The legacy straight-line motor curve is a scenario, not qualification.
R39Knee actuator at the knee in V1; knee gravity spring in scope; no parallel / five-bar leg2026-09-27. Hip-driven knee linkage is a V2 refinement. research/knee-linkage.md.
R40V1 terrain: flat + 1" sills + ~20° slopes2026-09-27. Rough outdoor ground is V3 / Phase E (controls + perception), not a leg change.

Soft requirements#

IDRequirementNotes
R24V1 mass aspirational 4–5 lb / under 6 lb — historical soft preference onlySteve 2026-09-21: budget is explicitly blown / soft. Capability and packaging over the old number. Not a gate. Sketch: mechanical.md.
R28All-stepper is not the baselineResidual risk only. If later forced onto roll: closed-loop, minimal-backlash belts, accept lower one-leg bandwidth. Do not fake a CoG shift in software. Do not delete the V1 roll axis. Wheels stay FOC (R6).

Current architecture and milestones#

  • Four layers remain: CAN actuators → portable control core → real-time MCU → ROS 2 companion. A 1 kHz estimator does not require every CAN node to update at 1 kHz.
  • No Hux components are purchased/ordered. Historical personal electronics are unverified reuse possibilities, not free BOM inventory. parts-on-hand.md.
  • Keep 24-inch height / 14-inch width as the compact target. The approximately 26-inch candidate and different landing track are explicit alternatives requiring a decision, not silent requirement changes.
  • H1 head, link lengths, wider contacts, ankle mechanism and actuator reductions remain candidates. head-and-leg-review.md.
  • Choose the support mechanism; find a continuous full-step path with real joint centers and swept clearances; mock up packages; test one representative axis and contact assembly; validate single support; only then buy the remaining set.
  • Existing modes precede autonomous motion. Supported PARKED requires a rest support; power loss is not a guaranteed safe park.
  • V1 one-step success is 9/10 (R37). Neither a floor hop nor individually reachable poses passes it. Both feet must finish on the upper tread.

2026-09-28 engineering gates#

IDRequirementAcceptance evidence
R41Fix single support and full stair geometry before full-set procurementContinuous, collision-free complete step plus controlled support/return; no hidden extra joint or clamped reach
R42Itemized head mass properties and explicit coordinate transformsMass, CoM, inertia, units, status and revision; pack position is not whole-head CoM
R43Firm decisions cascade as one revisionCAD joint centers, contact geometry, BOM, dynamics and firmware joint map agree; historical models labeled
R44Stationary thermal and bus-load budgets are realMounted duty test; timestamped joint data, bus utilization/deadline measurements, transient/regen validation

Working milestones: NOTES.md. All proposed changes are logged in decisions.md.