HUXMechanical project
WorkshopDocumentsSingle-leg bench session recordV1-PROOF · R05 current build

Single-leg bench session record#

Copy this template for each test session. If a test is not done, leave its box unchecked. Obey the bench plan. The creation of this file does not complete a physical test.

Setup#

  • Date / operator / session ID:
  • Purpose and stage:
  • Motor, driver and servo exact models / quantity / serial or bus ID:
  • Controller / interface / firmware version / host revision:
  • Supply model / output voltage / current limit / grounding arrangement:
  • Actuator current-limit setting / verification method:
  • Fuse / wire / physical cut / catch fixture / return-energy protection:
  • Logic rail / encoder level conversion:
  • Link centers / pivot separation / reduction / wheel diameter:
  • Neutral reference / sign mapping / physical and software travel limits:
  • Load, force direction, lever arm and assembly self-weight contribution:
  • Planned duration / speed / acceleration:
  • Predeclared stop limits: voltage ___ / measured current ___ / temperature ___ / tracking error ___ / stale feedback ___:
  • Photo, wiring drawing and log paths:

Before motion#

  • The exact actuator voltage variant and the connector polarity are confirmed.
  • The fixture is clamped. The catch supports the mechanism with the torque off.
  • The passive sweep is checked. The cables and the wheel are clear.
  • The current limits, fuse, return-energy path and independent power cut are checked for this test.
  • The sign and the neutral are measured. The targets are bounded. No lock pin is engaged on an energized leg.
  • The readback is fresh. The first target matches the supported current position.
  • There is no automatic enable or sweep on connect/reset.

Measurements#

Trial / commandActual angle or rpmError / backlashRail min/maxCurrent (state what/where measured)Start/end/peak temperatureResult / stop reason

Fault checks, when implemented#

  • The software stop behavior is observed.
  • The deadman release and the command timeout are observed.
  • The host disconnect / controller reset is observed.
  • The servo communication loss / missing wheel feedback is observed in a supported test.
  • The physical cut works without laptop or controller cooperation.
  • A reconnect / reset / fault clearance produces no motion until a deliberate rearm.
  • Both actuator feeds are tested. The servo hold after loss of communications is contained.

Outcome#

  • Passed stages (with evidence):
  • Failures / unexpected motion / resets / binding / transients:
  • Changed assumptions or dimensions:
  • Next bounded test:
  • Qualification still open: