Stair candidate — corrected feasibility status#

Historical study — superseded for procurement on 2026-09-28. Current head/leg review reopens single support, geometry and actuator sizing. No components purchased. Old purchase claims, 7 N·m stationary-hold assumptions, pack=body CoM, and two-bus 1 kHz claims must not be used to buy/build. Historical numbers below are preserved, not revalidated.

The 9.5-inch rise × 9.5-inch going remains a design target. The current candidate is rejected. The earlier planar momentum window did not establish a working stair gait. See the sourced audit and correction record.

Geometry and balance#

spatial.js now supplies a single chain for both stair projections: body → hip roll → hip pitch → knee → axle spacer → wheel. It preserves both 7.5-inch links, the 0.975-inch outboard axle offset and joint travel limits. Inverse kinematics returns an achievable pose plus the requested target and its residual. The drawings show misses instead of stretching the links or independently moving the front view.

Whole-robot CoM includes body, hip assemblies, knees and wheels. Gravity moment about a contact and gravity holding demand at a hip are separate quantities. Aligning CoM over the tire does not make hip holding torque zero. The rigid tire support point changes with camber; being within the tire's drawn width is not proof of balance.

At the default settings, 197 of 201 sampled frames fail spatial reach, travel or projected terrain clearance. Maximum axle-target error is about 4.11 inches. The preliminary 2D collision check can reject a pose; passing it does not certify 3D clearance.

Historical planar reference#

The original sagittal path, timing, Jacobian loads and reduced momentum simulation remain available as referenceClimbFrame. They help explain why the old candidate fails, but their loads are not the loads of the corrected spatial poses.

Reference resultImplication
Knee static peak 10.56 N·m; dynamic peak 19.12 N·mA 12 N·m cap cannot reproduce the requested motion.
Hip pitch dynamic peak 6.74 N·mRequires a verified torque-speed and thermal envelope, not just a peak rating.
Wheel peak 4.03 N·mExceeds the 3 N·m working cap.
32 rejected shove samples with strict contact checksThe old small-normal-force exception concealed infeasible force allocation.
5.64-second playback cycleThis is requested timing, not demonstrated climb speed.

Contact feasibility requires nonnegative normal force, abs(F_tangent) <= μ F_normal, and available wheel torque. At zero normal force, there is no tangential traction. All reference phases and seams are inspected; the verdict cannot turn green merely because the reduced momentum calculation crests.

Previous recommendations to put the pack 1–2 inches forward, aim toward the rear of the tread, or accept a ±6% throw window are unvalidated sensitivity studies. Do not fix the mass layout or buy motors from those results. Increasing torque or friction cannot repair an unreachable mechanism pose.

Required next design result#

A replacement gait must solve both legs together, with body translation/orientation, contact states and finite tire support. Constrain joint travel, 3D self/terrain collision, unilateral contacts, traction, torque-speed, joint velocity, and acceleration continuously, including phase boundaries. Then calculate inverse dynamics for that same trajectory and test feedback recovery under uncertainty.

Before stair trials, demonstrate repeated entry, hold and exit from true single support on a tether. Require the free tire to be clear and unloaded; the current two-contact poise does not pass that gate. Test tread landings and capture from measured position and velocity errors. Descent needs its own trajectory, impact and regeneration analysis; ascent does not validate it.

No spatial stair controller or descent controller has been implemented. The sandbox continues to expose experimental behaviors, and reports observed support separately from requested mode.

Hip-roll rethink (open — R16 still IN V1)#

Steve, 2026-09-25: he does not like the hip-pivot unload that puts the robot onto one foot. It seems to work poorly. Do not lift hip roll from V1 (R16). Log the dislike and keep the rethink open.

Bad feel may be the wrong stair trajectory, the two-contact poise, or sim contact, not proof the DOF is useless. One concrete piece of it was found and fixed on 2026-09-25: the one-leg controller pivoted on the hub, and a crowned tire cambered 24° touches the floor an inch from under its hub, so the poise was sitting on its own bail-out threshold (sim-sandbox.md). Separate:

  1. Need some lateral CoG path to unload a wheel.
  2. Is hip roll the cheapest DOF for that path.
  3. Is the current stair path asking an infeasible throw — this candidate is already rejected above and in model-corrections.md.

Worked on 2026-09-26 in one-leg-stance.md: (1) the lateral path is the parallelogram hip-roll shift, 24.7° at the 92% stance; (2) hip roll is the right DOF for the shift and the poise, and no DOF on this robot gives a static one-wheel hold (an acrobot with 2–3 mm of capture region); (3) the stair needs a short flight (≤ 0.3 s from a ±20 mm CoM estimate) from a known inboard margin, not a hold. The planted hip roll holds ~8.3 N·m whenever a wheel is up — the "0 if the sway is done first" above was the tipping moment, not the joint torque.

Decision log: ../decisions.md. Mechanical lock language is unchanged: ../mechanical.md.

2026-09-26 — with the locked actuator masses#

actuators.js (temporary lock) puts 1.9 kg of actuator in the legs and hips and takes the picture to 7.75 kg. Re-running the 2D climb solver on the settled geometry:

Body CoM ahead of the hip axesLiftoff momentumLeast to crest (with catch)Most the slot absorbsResult
00.90 kg·m²/s1.031.15does not crest ("reversed") — the rear-leg shove cannot throw the heavier legs
+1"0.900.790.94crests; margin 0.11, window 0.15
+1.5"0.900.680.83crests; margin 0.22

Static holds on the drawn path: knee 13.6 N·m standing up over the front wheel (was 10.6), hip swing 4.0. Drawn-path dynamic peaks (rough, the hand-drawn path has velocity kinks): knee 20–23, hip swing 11–12, wheel 4–6 N·m — against RS02 17 / RS00 14 / RS05 5.5 peak. The candidate stays rejected on spatial reach (model-corrections.md); the mass result is a second, independent reason, and it says the same thing the 2026-09-22 note said before it was retired as a decision: the body mass has to sit ahead of the hip axes for a step-to gait on this geometry.