PARKED STAIR-V1. V1-PROOF is the active numerical model. This publisher cannot overwrite the proof BOM.
Parked stair engineering candidate — revision 2026-09-28-B#
No components are purchased. There is no fabrication or full actuator-set release. Start with the review and decisions. No third-party Python packages are necessary.
python3 tools/engineering/review.py --write
python3 tools/engineering/test_review.py
baseline.json owns head allocations, mass estimates, geometry, study overrides,
electrical assumptions and the historical tube reference. bom.json owns budget
rows and their procurement gates. Generated outputs:
docs/research/head-leg-results.json: results and 91-frame paths for the compact, extended and narrow-entry candidates. The other cases have summaries only.cad/layouts/head-h1.svg: dimensioned head allocation.tools/living-drawings/engineering.html: parked stair review page.docs/archive/stair-v1/bom.md: archived budget, computed from quantities and unit ranges.
Coordinates in the input and result positions are mm, X forward, Y left, Z up.
The body datum is midway between the hip-roll axes. Inertia is kg·m², torque N·m,
mass kg, force N. angles_deg orders hip roll, hip pitch, knee flexion, ankle roll.
Positive pitch puts the thigh rearward. The shin pitch is hip_pitch − knee.
Left and right legs use opposite lateral offsets. In a selected upright wheel pose, the assumed ankle counter-roll equals negative hip roll. This assumption depends on an unbuilt pitch-level carrier, not on a motor bolted to the shin.
leg is the compact 24-inch target. The studies.taller_leg_overrides and then
studies.extended_leg_overrides form the approximately 27-inch wide-entry comparison. The studies.narrow_stance_overrides produce the narrow comparison: 120 mm track during the step plus a nominal 355.6 mm moving-width gate.
neutral_wheel_outside_width_mm defines the fixed axle/yoke offset at zero roll, not the swept envelope. The preferred candidate uses the 9.5-inch link override with that narrow stance, for 25.94-inch height.
The 24/25-inch narrow cases remain rejected. The high-mass
case adds the explicit 0.60 kg head uncertainty. Neither variant silently replaces
the requirement. The release flags of the report stay false, whatever the screen scores are.
The screen solves whole-robot static COM, split-offset spatial IK and gravity joint moments. A layered search connects feasible poses. Interpolation checks the limited clearance model between samples. The screen does not solve actuator dynamics, real contact compliance/friction, thermal duty, full swept solids, nosings, descent or the actual ankle linkage. The old eight-axis JavaScript simulation remains a labeled historical experiment. Its tests intentionally assert that its stair candidate fails.
When you accept a design revision, update the inputs and the dated decision entry. Then regenerate the outputs and check the physical invariants. Update requirements, CAD joint centers, inertia/contact model, BOM, firmware map and limits together. Never promote an unmeasured mass or a vendor heat-sink rating into a hardware fact.