HUXMechanical project
WorkshopDocumentsWorking notes — 2026-09-28V0-GENESIS · archive

PARKED STAIR-V1 — 2026-09-28. Preserved planning history. V1-PROOF now governs active work.

Working notes — 2026-09-28#

No components purchased. Fix the stair mechanism before the actuator set. This is Steve's current direction, superseding old ordered/on-hand claims and the temporary motor lock. Decision log retains the history.

Completed in this review#

  • Audited head envelopes, component mass/CoM assumptions, thermal ratings, CAN capacity and cost omissions.
  • Created H1 dimensioned front/side/plan and a machine-readable head, mass and budget source.
  • Added exact split-offset leg FK/IK and 91-sample complete-step screening. Compact candidate fails; 26-inch candidate has a connected path with 810 additional sampled checks, without dynamic/hardware validation.
  • Corrected current inventory, requirements, mechanical/electrical/software interfaces and procurement gates.
  • Preserved and labeled the old drawings/simulator as the legacy eight-axis experiment.

Next decisions and engineering work#

  1. Support mechanism: hip+ankle roll with finite-width wheel contacts and a real pitch-level carrier, or deployable positively locked landing shoes. Simple motor relocation and a free swivel are not fixes.
  2. Scale: retain the compact 24-inch target while exploring whether the approximately 26-inch/narrow-entry option with moving-width margin is acceptable. Do not silently relax it.
  3. Real trajectory: replace the assumed ankle carrier with real joints, validate all swept solids, and time/retime the connected 26-inch path within speed/acceleration/contact limits. Sampled static reach does not make a gait.
  4. Head hardware fit: pick exact battery/board/connector envelopes and mocked cable routes. H1's nominal allocation passes box separation only.
  5. Joint sizing: Narrow-entry gravity peaks of 6.61/3.92/7.89 N·m at roll/pitch/knee exceed the reference stationary ratings. Evaluate actual reduction or another axis with the mass/thermal/geometry cascade.
  6. Bench sequence: nonpowered full-size mockup, then one representative axis/contact assembly, mounted thermal test and 10-second controlled one-leg support/return before the rest of the set.
  7. Controller contract: explicit joint axes, SI frame, mass tensor, effective contact footprint, timestamped mixed-rate CAN and safe supported abort.

Full analysis: docs/head-and-leg-review.md. Current budget: docs/bom.md. Checklists: docs/checklists/mechanical-v1.md.

Research, license boundaries, COTS carbon spars, service access and the long-term digital-twin horizon remain. No new artwork, no firmware implementation and no component order. Steve subsequently authorized committing and pushing this review to main; all hardware validation gates remain open.